Skip to main content

Table 4 SVM single classifier error rate for ASSR ensemble averaged sweeps

From: 40-Hz ASSR fusion classification system for observing sleep patterns

Training subjects

Test subject

Training sweeps

Test sweeps

Error

A, B, C, D, E

F

500(50 W0 + 50 N3) × 5

100(50 W0 + 50 N3)

9%

A, B, C, D, F

E

500(50 W0 + 50 N3) × 5

100(50 W0 + 50 N3)

28%

A, B, C, E, F

D

500(50 W0 + 50 N3) × 5

100(50 W0 + 50 N3)

13%

A, B, D, E, F

C

500(50 W0 + 50 N3) × 5

100(50 W0 + 50 N3)

14%

A, C, D, E, F

B

500(50 W0 + 50 N3) × 5

100(50 W0 + 50 N3)

20%

B, C, D, E, F

A

500(50 W0 + 50 N3) × 5

100(50 W0 + 50 N3)

23%

  1. Of different training and test subjects for channel Fz-A1A2.